SignalScope X 13.1 Adds Support for miniDSP EARS Pro

Early this year, miniDSP released EARS Pro, a test fixture for headphones and earphones that, unlike the original EARS device, offers standard ear canal simulators (IEC 60318-4) and stereo output channels with a headphone amplifier (when purchased with the optional USB 2×2 audio interface). This makes the EARS Pro a much better device for performing dual-FFT-based frequency response measurements of both headphones and earphones. SignalScope X 13.1 adds specialized support for the EARS Pro test fixture’s USB audio interface and makes it so easy to get up and running with compensated frequency response measurements. When the interface is connected to your device, SignalScope will automatically read the serial number from its unique hardware identifier and download factory-supplied microphone sensitivity and […]

» Read more

Measured: iPhone 17 Pro microphone frequency response and directivity

Frequency Response I measured the frequency response of the iPhone 17 Pro microphone by positioning a lab-grade reference microphone (PCB model 378B02) approximately 1mm away from the phone (facing the mic) in our anechoic chamber. The reference mic was connected directly to input 1 of a model 485B39 dual channel USB interface. The iPhone microphone signal was routed directly to a USB-C to 3.5mm headphone adapter using SignalScope’s audio play through function (with measurement mode enabled) and from there to input 2 of the 485B39. The response between the 2 microphones was measured with SignalScope’s Dual FFT Analyzer (on a Mac) with the microphones facing toward and away from a loudspeaker which was generating a swept sine excitation signal. The […]

» Read more

Measured: iPhone 16 Pro microphone frequency response and directivity

Frequency Response In order to measure the frequency response of the iPhone 16 Pro’s microphone, a lab-grade reference microphone (PCB model 378B02 1/2-inch pre-polarized free-field condenser microphone) was positioned facing the iPhone mic approximately 1mm away from the phone within our anechoic chamber. The speaker was behind the PCB mic, facing the iPhone. Both microphone signals were fed into a 485B39 USB stereo ICP signal conditioner and the response of the iPhone relative to the reference mic was measured using SignalScope’s Dual FFT Analyzer. Then, the iPhone and PCB mic were rotated 180 degrees, keeping the same orientation and position relative to each other, and the response was measured again. The 2 resulting frequency response measurements were averaged. Each averaged […]

» Read more

Measured: iPhone 15 Pro Max microphone frequency response and directivity

In the early days of the iPhone app store, I posted frequency response measurements of some iPhone microphones, including before and after certain iOS updates. This post represents the beginning of a new effort to measure the performance characteristics of iPhone microphones. Similar to the recent post on the Vision Pro microphone, two important metrics will be frequency response (magnitude) as well as the directional response of the primary (bottom) iPhone microphone. Frequency Response In order to measure the frequency response of the iPhone’s microphone, a lab-grade reference microphone (PCB model 378B02 1/2-inch pre-polarized free-field condenser microphone) was positioned facing the iPhone mic approximately 1 mm away from it. The speaker was behind the PCB mic, facing the iPhone. Both […]

» Read more

Fast affordable headphone measurements with SignalScope X and miniDSP EARS

Measuring your headphones and in-ear monitors just got a whole lot easier! If you have been looking for a convenient and affordable way to check the performance of your headphones or IEM’s, the combination of SignalScope’s Dual FFT Analyzer and miniDSP’s EARS calibrated headphone measurement system offers a great solution.

» Read more

SignalScope Pro 4 for iOS uniquely identifies USB audio devices

SignalScope Pro version 4 can uniquely identify USB audio devices attached to iPhone, iPod touch, or iPad, and remember user settings for each device the next time it is connected. Direct support has been added for The Modal Shop’s model 333D01 USB digital accelerometer and miniDSP’s UMIK-1 USB measurement microphone.

» Read more